Sun Fire[tm] V250 Server: Field Information Notices
The following list does not include related external
storage FINs, unless they are specific to the system.
Implementation (Impl.):
M = Mandatory (Fully Pro-Active)
C = Controlled Pro-Active (per Sun Geo Plan)
R = Reactive (As Required) |
|
FIN
|
Impl.
|
Components
Affected |
Description |
| I1155-1 |
R
|
Sun Fire 3800
Sun Fire 4800
Sun Fire 4810
Sun Fire 6800
Sun Fire 2900
Sun Fire 4900
Sun Fire 6900
Sun Fire 12K
Sun Fire 15K
Sun Fire E20K
Sun Fire E25K
Sun Blade 1000
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Fire V210
Sun Fire V240
Sun Fire V250
Sun Fire V280R
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V880z
Sun Fire V890
Sun Fire V1280
Netra 20
Netra 240
Netra 440
Netra 1280 |
The overflow of a performance counter on UltraSparc-IIIi,
UltraSparc-III+ and UltraSparc-IV-based systems can lead to
the false indication of a parity error. |
| I1148-1 |
R
|
Sun Blade 1500
Sun Blade 2500
Sun Fire V210
Sun Fire V240
Sun Fire V250
Sun Fire V440
Netra 240
Netra 440
FRU,DIMM,2x256MB,SPD0,1,PC2100+ (540-6399-01)
FRU,DIMM,2x512MB,SPD0,1,PC2100+ (540-6400-01)
FRU,DIMM,2x1GB,SPD0,1,PC2100+ (540-6401-01)
DIMM,256MB,SPD0,1,PC2100&FASTER (370-7680-01)
DIMM,512MB,SPD0,1,PC2100&FASTER (370-7670-01)
DIMM,1GB,SPD0,1,PC2100&FASTER (370-7671-01) |
Minimum OBP version is required to support new DIMMs with
333MHz dual data rate. |
| I1070-1 |
C
|
Sun Fire V480
Sun Fire V880
Sun Fire V440
Sun Fire V250
Sun Fire V240
Sun Fire V210
Sun Fire 280R
Netra 20 |
Open Boot Prom 4.15 or later enhance diagnostic operation on
Sun Fire Volume and Netra 20 Server Product. |
| I1063-1 |
R
|
Sun Fire V250
SCSI Backplane (370-5959-01) |
The retaining latch on the SCSI backplane cable that mates to J501
on the SCSI backplane may not latch fully on the left handside. |
| I1044-1 |
R
|
Sun Fire 280R
Sun Fire V880
Sun Fire V880z
Sun Fire V480
Sun Fire V440
Sun Fire V210
Sun Fire V240
Sun Fire V250
Netra 240 |
Disconnecting of all AC power cords from the Volume Systems
Products (VSP) Servers during servicing will remove the
intended ESD discharge path. |
| I0760-2 |
R
|
Ultra Enterprise 3000
Ultra Enterprise 4000
Ultra Enterprise 5000
Ultra Enterprise 6000
Ultra Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 3800
Sun Fire 4800
Sun Fire 4810
Sun Fire 6800
Sun Fire 12K
Sun Fire 15K
Sun Fire 280R
Sun Fire V210
Sun Fire V240
Sun Fire V250
Sun Fire V440
Sun Fire V480
Sun Fire V880
Sun Fire V880z
Sun Fire V1280
Sun Fire E20K
Sun Fire E25K
Sun Fire E2900
Sun Fire E4900
Sun Fire E6900
Netra 20
Netra 1280
Sun Blade 1000
Sun Blade 1500 |
Sun Enhanced Memory DIMM Replacement Policy. |
|