Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

Sun Fire[tm] V1280 / Netra[tm] 1280 Server: Repair Procedures

This section provides the most common repair procedures for the Sun Fire V1280 / Netra 1280 which are included in the Sun Fire V1280 / Netra 1280 Service Manual (817-0510).

The following table provides the section numbers for each procedure.

Component
Remove
Install
Tips
Baseplane
12.1
12.2
 
CPU/Memory Boards
8.2.1
8.2.2
  • The Vcore setting for UltraSPARC IV 1350MHz boards should be 1.25V, but some earlier releases of firmware will power on and operate the board at an incorrect voltage. (FIN I1166-1).
  • EMI gaskets and spring fingers on Sun Fire V1280 and Netra 1280 boards may detach and cause component damage when they fall into the system (FIN I1035-1).
  • New installation procedure for Sun Fire V1280/Netra 1280 boards is now available (FIN I0993-1). See 817-2675 for the procedure.
  • A plunger assembly in the chassis may interfere with System Board 0 as it is slid into or out of the chassis (FIN I0974-1).
  • Sun Fire 3800/4800/4810/6800, V1280 and Netra 1280 systems may experience false data parity error messages (FIN I1020-1).
  • A limited set of Sun Fire System Boards may be vulnerable to Uncorrectable Errors in L2 SRAM. (FCO A0248-1).
DVD-ROM Drive
5.3.1
5.3.2
 
Hard Disk Drives
5.1.1
5.1.2
 
IB Fans
6.3.1
6.3.2
 
IB_SSC Assembly
9.1.1
9.1.2
  • EMI gaskets and spring fingers on Sun Fire V1280 and Netra 1280 boards may detach and cause component damage when they fall into the system (FIN I1035-1).
  • I/O System Controller (IB_SSC) assemblies for Sun Fire V1280 and Netra 1280 have been incorrectly left in Manufacturing Mode (FIN I1022-1).
  • New installation procedure for Sun Fire V1280/Netra 1280 boards is now available (FIN I0993-1). See 817-2675 for the procedure.
L2 Repeater Board
10.1
10.1
  • EMI gaskets and spring fingers on Sun Fire V1280 and Netra 1280 boards may detach and cause component damage when they fall into the system (FIN I1035-1).
  • New installation procedure for Sun Fire V1280/Netra 1280 boards is now available (FIN I0993-1). See 817-2675 for the procedure.
Main Fans
6.1.2
6.1.3
  • Main Fan 6 and Main Fan 7 failures can cause reduced system availability in Sun Fire V1280 and Netra 1280 servers (FIN I0924-1).
Main Fan Tray
6.2.1
6.6.2
 
Memory DIMMS
8.3.2
8.3.3
  • Best Practices Guide for Memory Errors for diagnosing UltraSPARC III memory errors now available (FIN I1018-1).
  • 512MB DIMMs are now supported in Sun Fire V1280 and Netra 1280 systems. (FIN I0961-2).
  • Diagnosing Main Memory errors versus L2SRAM errors on UltraSPARC III and UltraSPARC III Cu systems (FIN I0954-1).
  • Too many Memory DIMMs are being unnecessarily replaced on the UltraSPARC II, III, III+, IIIi and, IV families of systems, increasing customers' service actions and related system downtime. (FIN I0760-2).
PCI Cards
9.2.1
9.2.2
 
Power Distribution Board
7.3.1
7.3.2
 
Power Inlet Box
7.2.1
7.2.2
 
Removable Media Module
5.2.1
5.2.2
  • Attempting to remove the SCSI cable from a Sun Fire V1280/Netra 1280 Media Bay, or the SCSI Card Reader cable that connects to the SSC card reader, will result in damage to the server (FIN I1052-1).
Power Supplies
7.1.1
7.1.2
 
SCC Reader
5.5.1
5.5.2
  • Attempting to remove the SCSI cable from a Sun Fire V1280/Netra 1280 Media Bay, or the SCSI Card Reader cable that connects to the SSC card reader, will result in damage to the server (FIN I1052-1).
System Indicator Board
11.1
11.2
 
Tape Drive
5.2.1
5.2.2
 
 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.
 Legal Terms Privacy Policy Feedback