| InfoDoc
|
Synopsis
|
| 80696 |
Tripped breaker after Sun StorEdge[TM] D240 power supply failure. |
| 79943 |
Sun Fire[TM] (Serengeti) Midrange System: System Board Upgrade Requirements |
| 79833 |
Understanding and Troubleshooting VCMON & CSTH-LITE errors |
| 79014 |
Sun Fire[TM]: Replacing CPU / Memory or I/O boards requires that the firmware matches existing boards |
| 78838 |
Sun Fire[TM] PCI IOMMU TLB ERROR |
| 78415 |
Obtaining FRU Data information from a Sun Fire[TM]
3800/4x00/6800 Server |
| 76828 |
How to Check for System Controller v2 (Version 2 System Controller) |
| 76684 |
Sun Fire[TM] 3800-6800: How to run higher levels of POST using testboard |
| 76507 |
Sun Fire[TM] Serengeti and Amazon (4[89]00-6[89]00): Physical Device Mapping for 8 slot PCI+ I/O boards with XMITS |
| 76294 |
Sun Fire[TM] Servers: How L2CheckErrors Happen |
| 76235 |
Sun Fire[TM] Mid-Range Servers Features and Requirements Matrix |
| 76187 |
Sun Fire(TM) System Controller Logger package
(SUNWsclog)
|
| 76108 |
Elapsed Time Required for Various Sun Fire[TM] testinterconnect Command Options |
| 75806 |
Sun Fire[TM] Mid-Range Servers: Auto-Diagnosis and Recovery Feature and Requirements Matrix |
| 75538 |
Sun Fire[TM] Server: Using ECC Syndrome History to Troubleshoot Uncorrectable Errors (UE) in Memory |
| 75433 |
Sun Fire[TM] 3800/4800/4810/6800: System Controller with Firmware 5.15.3 / 5.15.4 may encounter regression of behavior cited in Bug 4449986 |
| 74982 |
5.17.0 firmware update procedure for Sun Fire[TM] entry-level midrange systems |
| 74436 |
Sun Fire[TM] 3800-6800: Switching from domain console to domain shell using ssh |
| 74192 |
Trouble-shooting Sun Fire[TM] 3800-6800 Server System Controller failover |
| 73312 |
CPU Nomenclature in Sun Fire[TM] Midrange Servers |
| 73133 |
Collecting Sun Fire[TM] 3800-6800 and E4900/E6900 Hardware Data |
| 73050 |
Dynamic Reconfiguration(DR): Frequently Asked Questions(FAQs) as they apply to the Sun Fire[TM] 3800-6800, 12K/15K and E20K/E25K Servers. |
| 72784 |
Data Required to Obtain an Authorization Code for a Replacement System Board for Sun Fire[TM] 3800(R)/48xx(R)/6800 Servers
|
| 72539 |
Sun Fire[TM] V1280-E15000:Tech Tip:An offline
d processor can be involved in a panic in rare cases |
| 72485 |
How to set up platform agent to monitor Sun Fire[TM] 3800-6800 servers |
| 72433 |
How to analyze showresetstate output and CPU REDMODE states |
| 72350 |
Sun Fire[TM] 3800(R)/4800(R)/4810(R)/6800 Server I/O Card Probe Order |
| 72163 |
Solaris[TM] 8 and 9 Operating System Availability Features |
| 72159 |
Processor may be incorrectly offlined when it encounters a UCC + ME bit set in AFSR |
| 72045 |
Breakdown of non-cacheable address space in Sun[TM] Fire 3800(R)/4800(R)/4810(R)/6800, & V1
280 Servers, and the Netra[TM] 1280 Server. |
| 72044 |
Bus Error (BERR) Event on CPUx" reported in the Solaris [TM] software panic string might lead to improper System Board replacement |
| 72000 |
How to capture the power-on date of system using Sun[TM] Explorer 4.2 Software? |
| 71990 |
What do the different settings for automatic_cpu_removal do? |
| 71818 |
How to gather 'prtfru -x' info for Sun Fire[TM] xx00 platforms without having Sun[TM] Explorer installed |
| 71740 |
Understanding Memory Interleaving on Sun Fire[TM] Hardware
|
| 71591 |
How to debug ECC syndrome 0x071 or uncorrectable ECC errors on Sun Fire[TM] 1280-15K servers. |
| 71494 |
Address Parity errors on Sun Fire[TM] System Boards
|
| 71390 |
Sun Fire[TM] 3800-6800 Server System Controller failover
|
| 70973 |
Sun Fire[TM] High/Midrange Servers: MTag Syndrome Table
|
| 70966 |
Sun Fire[TM] 3800 - 6800 FW version matrix
|
| 70962 |
Sun Fire[TM] Midrange Servers: Decoding data bit to a pair of DIMMs
|
| 70933 |
Sun Fire[TM] 3800-6800: Where to locate instructions for FRU replacement |
| 70829 |
Incorrect FRU reported as failed on Sun Fire[TM] |
| 70496 |
Sun Fire[TM] 3800-6800: How do I find the Schizo version number? |
| 70434 |
Sun Fire[TM] 3800-6800: 5.15.0 firmware introduces two new commands and four new platform parameters in service mode |
| 70433 |
Sun Fire[TM] 3800-6800: Where can I get the service mode pass word? |
| 70419 |
Sun Fire[TM] 3800-6800: What can occur if a system has two System Controllers and SC failover is disabled? |
| 70317 |
Benefits of upgrading the Solaris[TM] 8 KUP (Kernel Update Patch) on UltraSPARC(R)-III/UltraSPARC(R)-IIIplus platforms |
| 70301 |
Performance differences Sun Fire[TM] 15K between Sun Fire[TM] 6800 |
| 70231 |
POST Memory Addressing failures difficult to troubleshoot to FRU |
| 70181 |
Sun Fire[TM] 3800-6800: What does ""chs"" in the POST column of showcomponents indicate? |
| 70173 |
Sun Fire[tm] 3800-6800: How do the clocks work? |
| 52980 |
Changing clock on the system controllers |
| 51645 |
Sun Fire[TM] 3800-6800/12K-E25K servers: What is Capacity on Demand (COD) and what are its commands?
|
| 51580 |
Tech Tip: Sun Fire[TM] 3800-6800 Initial Data collection |
| 50831 |
Sun Fire[TM] 3800-6800 servers: How to monitor Capacity on Demand (COD) 2.0 |
| 50827 |
Sun Fire[TM] 3800-6800 servers: Setting up a platform for Capacity On Demand (COD) 2.0 |
| 50826 |
Sun Fire[TM] 3800-6800 servers: Capacity on Demand 2.0 part number and license requirements |
| 50824 |
Sun Fire[TM] 3800-6800: Why can the platform shell override a domain's ACL list? |
| 50822 |
Setting up SNTP Client on a SunFire[TM] 3800-6800 |
| 50802 |
Sun Fire[TM] 3800-6800 servers: How to Recover a Lost Domain
Password |
| 50608 |
AC Input Box switch in a Sun Fire[TM] 6800 can turn off by it self |
| 50605 |
Sun Fire[TM] 6800 server: Location of Repeater Boards 10, 11, 12, and 13 |
| 50393 |
Sun Fire [TM] 3800-6800 AC/DC Power Distribution |
| 50275 |
Process to follow when creating a product quality escalation on a Sun Fire[TM] HighEnd/MidFrame Server.
|
| 49903 |
Sun Fire [TM] 6800/4810/4800/3800 CPU & Memory Document
|
| 49781 |
Sun Fire[TM] Midrange (3800/4800/4810/6800) I/O Assembly (I/O Boat) Document
|
| 49829 |
Sun Fire [TM] midrange servers' Power Grid(s) |
| 49649 |
Sun Fire[TM] 3800-6800: Upgrading the firmware from 5.11.X or 5.12.X to 5.14.X |
| 49293 |
Sun Fire[TM] 3800-6800: Non Cacheable Address Space tables for the Sun Fire[TM] 3800-6800, and the Netra[TM] 1280 Server
|
| 49245 |
Sun Fire[TM] 6800: What happens if one power grid fails? |
| 49242 |
Sun Fire[TM] 6800, 4800, 4810, 3800: How are MAC addresses assigned to domains? |
| 49202 |
Sun Fire[TM] 3800-6800: CPU/Memory Board Dynamic Reconfiguration (DR) Considerations |
| 49128
|
Sun Fire [TM] 3800/48x0/6800 Frame Manager FAQ |
| 47950 |
What is the command used to display the serial number of a Sun Fire [TM] 3800/
4800/4810/6800 machine remotely ? |
| 47824 |
Device Paths for the Sun Fire [TM] 3800/4800/4810/6800 I/O Assemblies |
| 46780 |
Sun Fire[TM] 3800-6800: Instructions on how to gather data from a hung domain. |
| 45890
|
Sun Fire[TM] 3800-6800: Firmware revision 5.13.x issues and work arounds |
| 44503 |
How to run extended explorer on a Sun Fire[TM] SFx8x0 System. |
| 43631 |
Sun Fire[TM] (3800-6800): Navigating Between Shells |
| 43382 |
Requirements for Dynamic Configuration on the Sun Fire [TM] Servers |
| 42950 |
Sun Fire[TM] 3800/4800/4810/6800 Systems flashprom update shortcut |
| 42861 |
Q & A about Dynamic Reconfiguration (DR) on Sun
Fire 3800 - 6800 |
| 41723 |
Updating the Sun Fire[TM] 3800-6800 series Flash Proms |
| 41342 |
Sun Fire example of dumpconfig and restoreconfig |
| 28285 |
Sun Fire (3800-6800) - Centerplane/ID board configuration
answers |
| 27553 |
How to configure a loghost on Sun Fire[TM] 3800-6800 and E4900/E6900 servers |
| 27538 |
How to gather information at the OK prompt |
| 27432 |
Sun Fire (3800-6800): Physical Device Mapping for I/O boats |
| 27431 |
Sun Fire (3800-15000, 880, 280R): Marketing Product Names and Former Codenames History |
| 27430 |
Sun Fire (3800-6800): Layout of memory on CPU/System boards |
| 27428 |
Sun Fire[TM] (3800-6800) System Controller Application (ScApp)
How To's |
| 26286 |
Sun Fire[TM] 3800-6800: System Controller failover functionality |
| 24656 |
Solaris continued to run without any message in /var/adm/messages
and no "service" LEDs were lit after a fault was injected on the Sun Fire
Fireplane Interconnect |
| 18474 |
Flashprom Patches / Minimum OE revisions for Sun [TM] Systems |