Netra[tm] 440 Server: Field Information Notices
The following list does not include related external
storage FINs, unless they are specific to the system.
Implementation (Impl.):
M = Mandatory (Fully Pro-Active)
C = Controlled Pro-Active (per Sun Geo Plan)
R = Reactive (As Required) |
|
FIN
|
Impl.
|
Components
Affected |
Description |
| I1155-1 |
R
|
Sun Fire 3800
Sun Fire 4800
Sun Fire 4810
Sun Fire 6800
Sun Fire 2900
Sun Fire 4900
Sun Fire 6900
Sun Fire 12K
Sun Fire 15K
Sun Fire E20K
Sun Fire E25K
Sun Blade 1000
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Fire V210
Sun Fire V240
Sun Fire V250
Sun Fire V280R
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V880z
Sun Fire V890
Sun Fire V1280
Netra 20
Netra 240
Netra 440
Netra 1280 |
The overflow of a performance counter on UltraSparc-IIIi,
UltraSparc-III+ and UltraSparc-IV-based systems can lead to
the false indication of a parity error. |
| I1148-1 |
R
|
Sun Blade 1500
Sun Blade 2500
Sun Fire V210
Sun Fire V240
Sun Fire V250
Sun Fire V440
Netra 240
Netra 440
FRU,DIMM,2x256MB,SPD0,1,PC2100+ (540-6399-01)
FRU,DIMM,2x512MB,SPD0,1,PC2100+ (540-6400-01)
FRU,DIMM,2x1GB,SPD0,1,PC2100+ (540-6401-01)
DIMM,256MB,SPD0,1,PC2100&FASTER (370-7680-01)
DIMM,512MB,SPD0,1,PC2100&FASTER (370-7670-01)
DIMM,1GB,SPD0,1,PC2100&FASTER (370-7671-01) |
Minimum OBP version is required to support new DIMMs with
333MHz dual data rate. |
| I1101-1
|
R
|
Netra 440
Netra 440
ASSY,MRBD w/CPU cage, CHLPA (540-5418-XX)
FRU,ASSY,MOTHERBOARD,NETRA440 (540-5919-XX)
| Damage to Motherboard connector could occur during removal of
ALOM Card from Sun Fire V440 or Netra 440.
|
| I1099-1 |
R
|
Sun Fire V440
Netra 440
ASSY,MRBD w/CPU cage, CHLPA (540-5418-XX)
FRU,ASSY,MOTHERBOARD,NETRA440 (540-5919-XX)
| Sun Fire V440 and Netra 440 systems using a specific networking configuration may unexpectedly reset.
|
| I1098-1 |
R
|
Netra 440
Sun Fire V440
X7415A 1.062GHz 2GB DDR1 SFV440
X7416A 1.28GHz 4GB DDR1 SFV440
ASSY A42 1.064GHz 0MB CPU BD (501-6369-03)
ASSY A42 1.280GHz 0MB CPU BD (501-6370-04) |
System may fail self-test with "OBP (Open Boot PROM) not responding"
on Sun Fire V440 and Netra 440. |
| I1073-1 |
R
|
StorEdge LTO2 Tape Drive (380-0914-01) |
Sun Fire V440 does not boot if LTO2 Desktop Tape Drive (with firmware
F3AD) is connected to the on-board SCSI port. |
| I1044-1 |
R
|
Sun Fire 280R
Sun Fire V880
Sun Fire V880z
Sun Fire V480
Sun Fire V440
Sun Fire V210
Sun Fire V240
Sun Fire V250
Netra 240 |
Disconnecting of all AC power cords from the Volume Systems Products (VSP)
Servers during servicing will remove the intended ESD discharge path. |
|