| Implementation (Impl.):
M = Mandatory (Fully Pro-Active) C = Controlled Pro-Active (per Sun Geo Plan) R = Reactive (As Required) |
| FIN | |
Components Affected | Description |
| I1166-1 |
R
|
Sun Fire v1280 Sun Fire 12K Sun Fire 15K Sun Fire E20K Sun Fire E25K Sun Fire 4800 Sun Fire 6800 Sun Fire E2900 Sun Fire E4900 Sun Fire E6900 ASSY BBLW8 CPU400 S1350 GJG (540-6295-01) ASSY BBUNI CPU400 S1350 GJG (540-6298-01) |
The Vcore setting for UltraSPARC IV 1350MHz boards should be 1.25V, but some earlier releases of firmware will power on and operate the board at an incorrect voltage. |
| I1157-1 |
R
|
Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire 2900 Sun Fire 4900 Sun Fire 6900 Sun Fire 12K Sun Fire 15K Sun Fire E20K Sun Fire E25K Sun Fire V1280 Netra 1280 |
Dynamic Reconfigurations (DR) error on a Mid-Range and High-End Server Platforms should be root caused and corrected. |
| I1155-1 |
R
|
Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire 2900 Sun Fire 4900 Sun Fire 6900 Sun Fire 12K Sun Fire 15K Sun Fire E20K Sun Fire E25K Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Fire V210 Sun Fire V240 Sun Fire V250 Sun Fire V280R Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V880z Sun Fire V890 Sun Fire V1280 Netra 20 Netra 240 Netra 440 Netra 1280 |
The overflow of a performance counter on UltraSparc-IIIi, UltraSparc-III+ and UltraSparc-IV-based systems can lead to the false indication of a parity error. |
| I1138-1 |
R
|
Sun Fire 4800 Sun Fire 4810 Sun Fire E4900 Sun Fire 6800 Sun Fire E6900 Quad Fast Ethernet (QFE) PCI Adapter X1034A Sun Quad FastEthernet (QFE/P) 501-5406-01 Sun Quad FastEthernet (QFE/P) 501-5406-06 Sun Quad FastEthernet (QFE/P) 501-5406-07 |
The QFE network interface is reporting excessive input packet errors when running back to back stress tests. |
| I1131-1 |
R
|
Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire V1280 Sun Fire E2900 Sun Fire E4900 Sun Fire E6900 Sun Fire 12K Sun Fire 15K Sun Fire E20K Sun Fire E25K Netra 1280 |
CPU/Memory board memory drain during Dynamic Reconfiguration may take a long time to complete without patches for Solaris 8 and 9. |
| I1122-1 |
R
|
Sun Fire E2900 Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire E4900 Sun Fire 6800 Sun Fire E6900 Sun Fire V1280 Netra 1280 Sun Fire 12K Sun Fire 15K Sun Fire E20K Sun Fire E25K |
When replacing components (CPU/Memory boards, MaxCPU boards, (c)PCI I/O boards, System Controllers, Repeater boards, Expander boards, System Control Peripheral boards, and hsPCI(+) boards) on Mid-Range and High-End Servers, be sure to remove the VHDM cover and inspect the connectors before insertion. |
| I1109-1 |
R
|
Any parts involved in suspected thermal incidents on any Server/Desktop Products | Request for any parts involved in suspected thermal incidents on any Server/Desktop Products be returned via Customer CPAS. |
| I1085-1 |
R
|
Sun Fire E2900 Sun Fire E4900 Sun Fire E6900 1.2 Ghz 4x1200Mhz Jag Proc Uniboard, 0GB (540-6038) 1.050Ghz 4x1050Mhz Jag Proc Uniboard, 0GB (540-6077) 1.2Ghz 4x1200Mhz Jag Proc Uniboard 8GB (540-6006) 1.05Ghz 4x1050Mhz Jag ProcUniboard 8GB (540-6003) 1.2Ghz 4x1200Mhz Jag Proc Uniboard 16GB (540-6004) 1.05Ghz 4x1050Mhz Jag Proc Uniboard 16GB (540-6001) 1.2Ghz 4x1200Mhz Jag Proc Uniboard 32GB (540-6005) 1.050Ghz 4x1050Mhz Jag Proc Uniboard 32GB (540-6002) 1.2 Ghz 4x1200Mhz Jag Proc Uniboard, 0GB (540-5940) 1.50Ghz 4x1050Mhz Jag Proc Uniboard, 0GB (540-5664) 1.2Ghz 4x1200Mhz Jag Proc Uniboard 8GB (540-5993) 1.05Ghz 4x1050Mhz Jag ProcUniboard 8GB (540-6000) 1.2Ghz 4x1200Mhz Jag Proc Uniboard 16GB (540-5938) 1.05Ghz 4x1050Mhz Jag Proc Uniboard 16GB (540-5662) 1.2Ghz 4x1200Mhz Jag Proc Uniboard 32GB (540-5939) 1.050Ghz 4x1050Mhz Jag Proc Uniboard 32GB (540-5663) |
POST MEM2 Test may run for a very long time on Sun Fire E2900, E4900, and E6900 systems and delay system start-up. This could increase system downtime during maintenance or delay system deployment at initial installation. There is no impact to booted domains. |
| I1080-1 |
R
|
Sun Fire 4800/4810/6800 Sun Fire E2900/E4900/E6900 Sun Fire V1280 Sun Fire Netra V1280 Sun Fire E2900 X4050A PCI I/O Assy SF Midrange Servers X2763A Sun Fire 4800/6800 Dual SC V2 ASSY TSTD SC RIO SERENGETI (501-5407-15 or lower) ASSY TSTD SC RIO LW8 (501-6459-02 or lower) ASSY SYSTEM CONTROLLER SDR LW8 (501-6779-02 or lower) ASSY L2 REPEATER LW8 (540-4974-06 or lower) ASSY CENTERPLANE SUN FIRE 6800 (501-4405-05 or lower) ASSY CENTERPLANE SUN FIRE 4800 (501-4406-07 or lower) ASSY SYSTEM BASEPLANE LW8 (501-6014-07 or lower) |
The Backplane/Centerplane VHDM connector on mid-range servers could separate from backplane during daughter card removal. |
| I0760-2 |
R
|
Ultra Enterprise 3000 Ultra Enterprise 4000 Ultra Enterprise 5000 Ultra Enterprise 6000 Ultra Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire 12K Sun Fire 15K Sun Fire 280R Sun Fire V480 Sun Fire V880 Sun Fire V880z Sun Fire V1280 Sun Fire E20K Sun Fire E25K Sun Fire E2900 Sun Fire E4900 Sun Fire E6900 Netra 20 Netra 1280 Sun Blade 1000 |
Too many Memory DIMMs are being unnecessarily replaced on the UltraSPARC II, III, III+, IIIi and, IV families of systems, increasing customers' service actions and related system downtime. |
|
Copyright 1994-2005 Sun Microsystems, Inc., All rights reserved. Legal Terms Privacy Policy Feedback | |||