| FIN |
Impl.
|
Components
Affected |
Description |
| I1158-1 |
R
|
Sun StorEdge 6320 Array |
The Sun StorEdge 6320 Restore CD fails to restore the system
from flash disk. |
| I1153-1 |
R
|
Sun StorEdge 6320 Array
Sun StorEdge 6920 Array |
NTC (Network Terminal Concentrator) Timeout issue encountered
during configuration of a SPA Tray FRU replacement or system
reload/restore from Recovery CD. |
| I1146-1 |
C
|
Sun StorEdge 6320 Array |
StorEdge 6320 Systems with MIRE 1.2.3.1 Service Processor
software will not complete an "unconfigure" operation. |
| I1143-1 |
R
|
Sun StorEdge 6320 Array |
'logadm' on the SE6320 image is not restarting syslogd resulting
in missed log messages and false positive StorADE alarms. |
| I1136-1 |
R
|
Seagate ST336607FC (36GB)
Seagate ST373307FC (73GB)
Seagate ST146807FC (146GB)
Seagate ST336607LC (36GB)
Seagate ST373307LC (73GB)
Seagate ST146807LC (146GB)
|
Improved firmware for Seagate 10K.6 disk drives will reduce
the incidence of unexpected outages due to a spindle motor issue.
|
| I1125-1 |
M
|
Sun StorEdge 6320 Array
Sun StorEdge 6120 Array
ASSY T4 2.5 CONTRLR W/SLED (540-5559-XX) |
StorEdge 6120 and 6320 Arrays with firmware prior to 3.1.x may
experience downtime or data integrity if double disk errors or
back-end loop hangs occur. |
| I1107-1 |
R
|
Sun StorEdge 6320 System
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array |
Batteries may be marked as "failed" and health checks may not
run in Sun StorEdge 6020/6120 Arrays having 3.0.x firmware. |
| I1106-1 |
C
|
Sun StorEdge 6320 System
X6815A SE6120 73GB 10K HDD (540-5330-02)
X6817A SE6120 146GB 10K HDD (540-5471-02) |
SE6320 Baseline Patch Release 1.2.2 may load Drive FW while
disk scrubber is running. |
| I1072-1 |
R
|
Sun StorEdge 6320 System |
How to obtain and use the various software images for the
Sun StorEdge 6320 System. |
| I1043-2 |
M
|
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array
Sun StorEdge 6320 System
ASSY, T4 2.5 Controller (540-5559-xx)
|
A specific group of Sun StorEdge 6120 Arrays and 6320 Systems may reset in
rare circumstances due to a controller interrupt caused by an SRAM timing issue.
There may be the potential for silent data corruption if this occurs. |
| I1039-1 |
R
|
Sun StorEdge 6320 System |
Correct procedure for converting a 2X4 configuration to two 2X2 configurations. |
| I1023-1 |
R
|
StorEdge Network 2GB FC Switch-8 (540-5554)
StorEdge Network 2GB FC Switch-16 (540-5404)
|
StorEdge Network 2GB Switch-8 and Switch-16 units which have been running
for 25 to 28 days may not recognize any attached devices if the
devices are rebooted. This occurs due to a switch firmware bug and can
be resolved with a firmware upgrade. |
| I1009-2 |
M
|
All Sun StorEdge 6020 Arrays
All Sun StorEdge 6120 Arrays |
During power on (cold boot) of a Sun StorEdge 6020/6120 Array
or Sun StorEdge 6320 system one or more drives may come up
in an offline state. |
| I0959-1 |
R
|
BROCADE 12000 SWITCH 32 PORTS (370-5748-01)
BROCADE 12000 SWITCH 64 PORTS (370-5749-01)
BROCADE 12000 16-PORT BLADE (370-5449-01)
2GB 16 PORT SWITCH ASSY (540-5404-01)
SSY 8 PORT SAN 4.1 2GB (540-5554-01)
16 PORT SWITCH ASSY (540-4751-02 or lower)
ASSY 8-PORT FCA1 SW 01 (540-4372-03 or lower)
ASSY HOST ADAPTER PHOTON (501-5266-04 or lower)
ASSY OEM PCI DUAL NETWK ADAPT (375-3030-01)
ASSY OEM cPCI DUAL FC HBA (375-0118-03 or lower)
ASSY OEM 2GB DUAL PCI FC HBA (375-3108-01)
ASSY OEM 2GB PCI SGL FC HBA (375-3102-01)
|
Storage Automated Diagnostic Environment 2.2 (StorADE) is currently
installed on the Service Processor of the Sun StorEdge 3900 and 6900
series of storage products as the monitoring agent for the box, as well
as the interface to the solution configuration tools. However, many
customers and field personnel are not aware of the capabilities of
StorADE and do not activate this tool on these and other storage
products. In addition to being pre-installed on StorEdge 3900/6900 series
products, StorADE works with other storage products such StorEdge
T3/T3+, A5x00, A3500FC, StorEdge 6120, StorEdge 6320, and StorEdge
3510. |