Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 6320 System: Field Information Notices

 

Implementation (Impl.):
M
= Mandatory (Fully Pro-Active)

C
= Controlled Pro-Active (per Sun Geo Plan)

R
= Reactive (As Required)

For Sun Fire[tm] V100 specific FINs, click here.

For Sun StorEdge 6020/6120 specific FINs, click here.

FIN
Impl.
Components Affected Description
I1158-1
R
Sun StorEdge 6320 Array The Sun StorEdge 6320 Restore CD fails to restore the system from flash disk.
I1153-1
R
Sun StorEdge 6320 Array
Sun StorEdge 6920 Array
NTC (Network Terminal Concentrator) Timeout issue encountered during configuration of a SPA Tray FRU replacement or system reload/restore from Recovery CD.
I1146-1
C
Sun StorEdge 6320 Array StorEdge 6320 Systems with MIRE 1.2.3.1 Service Processor software will not complete an "unconfigure" operation.
I1143-1
R
Sun StorEdge 6320 Array 'logadm' on the SE6320 image is not restarting syslogd resulting in missed log messages and false positive StorADE alarms.
I1136-1
R
Seagate ST336607FC (36GB)
Seagate ST373307FC (73GB)
Seagate ST146807FC (146GB)
Seagate ST336607LC (36GB)
Seagate ST373307LC (73GB)
Seagate ST146807LC (146GB)
Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected outages due to a spindle motor issue.
I1125-1
M
Sun StorEdge 6320 Array
Sun StorEdge 6120 Array
ASSY T4 2.5 CONTRLR W/SLED (540-5559-XX)
StorEdge 6120 and 6320 Arrays with firmware prior to 3.1.x may experience downtime or data integrity if double disk errors or back-end loop hangs occur.
I1107-1
R
Sun StorEdge 6320 System
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array
Batteries may be marked as "failed" and health checks may not run in Sun StorEdge 6020/6120 Arrays having 3.0.x firmware.
I1106-1
C
Sun StorEdge 6320 System
X6815A SE6120 73GB 10K HDD (540-5330-02)
X6817A SE6120 146GB 10K HDD (540-5471-02)
SE6320 Baseline Patch Release 1.2.2 may load Drive FW while disk scrubber is running.
I1072-1
R
Sun StorEdge 6320 System How to obtain and use the various software images for the Sun StorEdge 6320 System.
I1043-2
M
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array
Sun StorEdge 6320 System
ASSY, T4 2.5 Controller (540-5559-xx)
A specific group of Sun StorEdge 6120 Arrays and 6320 Systems may reset in rare circumstances due to a controller interrupt caused by an SRAM timing issue. There may be the potential for silent data corruption if this occurs.
I1039-1
R
Sun StorEdge 6320 System Correct procedure for converting a 2X4 configuration to two 2X2 configurations.
I1023-1
R
StorEdge Network 2GB FC Switch-8 (540-5554)
StorEdge Network 2GB FC Switch-16 (540-5404)
StorEdge Network 2GB Switch-8 and Switch-16 units which have been running for 25 to 28 days may not recognize any attached devices if the devices are rebooted. This occurs due to a switch firmware bug and can be resolved with a firmware upgrade.
I1009-2
M
All Sun StorEdge 6020 Arrays
All Sun StorEdge 6120 Arrays
During power on (cold boot) of a Sun StorEdge 6020/6120 Array or Sun StorEdge 6320 system one or more drives may come up in an offline state.
I0959-1
R
BROCADE 12000 SWITCH 32 PORTS (370-5748-01)
BROCADE 12000 SWITCH 64 PORTS (370-5749-01)
BROCADE 12000 16-PORT BLADE (370-5449-01)
2GB 16 PORT SWITCH ASSY (540-5404-01)
SSY 8 PORT SAN 4.1 2GB (540-5554-01)
16 PORT SWITCH ASSY (540-4751-02 or lower)
ASSY 8-PORT FCA1 SW 01 (540-4372-03 or lower)
ASSY HOST ADAPTER PHOTON (501-5266-04 or lower)
ASSY OEM PCI DUAL NETWK ADAPT (375-3030-01)
ASSY OEM cPCI DUAL FC HBA (375-0118-03 or lower)
ASSY OEM 2GB DUAL PCI FC HBA (375-3108-01)
ASSY OEM 2GB PCI SGL FC HBA (375-3102-01)
Storage Automated Diagnostic Environment 2.2 (StorADE) is currently installed on the Service Processor of the Sun StorEdge 3900 and 6900 series of storage products as the monitoring agent for the box, as well as the interface to the solution configuration tools. However, many customers and field personnel are not aware of the capabilities of StorADE and do not activate this tool on these and other storage products. In addition to being pre-installed on StorEdge 3900/6900 series products, StorADE works with other storage products such StorEdge T3/T3+, A5x00, A3500FC, StorEdge 6120, StorEdge 6320, and StorEdge 3510.


 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.