Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 6020/6120 Array: Field Information Notices

 

Implementation (Impl.):
M
= Mandatory (Fully Pro-Active)

C
= Controlled Pro-Active (per Sun Geo Plan)

R
= Reactive (As Required)

FIN
Impl.
Components Affected Description
I1136-1
R
Seagate ST336607FC (36GB)
Seagate ST373307FC (73GB)
Seagate ST146807FC (146GB)
Seagate ST336607LC (36GB)
Seagate ST373307LC (73GB)
Seagate ST146807LC (146GB)
Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected outages due to a spindle motor issue.
I1125-1
M
Sun StorEdge 6320 Array
Sun StorEdge 6120 Array
ASSY T4 2.5 CONTRLR W/SLED (540-5559-XX)
StorEdge 6120 and 6320 Arrays with firmware prior to 3.1.x may experience downtime or data integrity if double disk errors or back-end loop hangs occur.
I1107-1
R
Sun StorEdge 6320 System
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array
Batteries may be marked as "failed" and health checks may not run in Sun StorEdge 6020/6120 Arrays having 3.0.x firmware.
I1043-2
M
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array
Sun StorEdge 6320 System
ASSY, T4 2.5 Controller (540-5559-xx)
A specific group of Sun StorEdge 6120 Arrays and 6320 Systems may reset in rare circumstances due to a controller interrupt caused by an SRAM timing issue. There may be the potential for silent data corruption if this occurs.
I1023-1
R
StorEdge Network 2GB FC Switch-8 (540-5554)
StorEdge Network 2GB FC Switch-16 (540-5404)
StorEdge Network 2GB Switch-8 and Switch-16 units which have been running for 25 to 28 days may not recognize any attached devices if the devices are rebooted. This occurs due to a switch firmware bug and can be resolved with a firmware upgrade.
I1009-2
M
All Sun StorEdge 6020 Arrays
All Sun StorEdge 6120 Arrays
During power on (cold boot) of a Sun StorEdge 6020/6120 Array or Sun StorEdge 6320 system one or more drives may come up in an offline state.
I1002-1
R
All Sun StorEdge 6020 Arrays
All Sun StorEdge 6120 Arrays
StorEdge 6020/6120 Arrays may automatically power themselves up after being placed in standby mode.


 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.