| FIN |
Impl.
|
Components
Affected |
Description |
| I1136-1 |
R
|
Seagate ST336607FC (36GB)
Seagate ST373307FC (73GB)
Seagate ST146807FC (146GB)
Seagate ST336607LC (36GB)
Seagate ST373307LC (73GB)
Seagate ST146807LC (146GB)
|
Improved firmware for Seagate 10K.6 disk drives will reduce
the incidence of unexpected outages due to a spindle motor issue.
|
| I1125-1 |
M
|
Sun StorEdge 6320 Array
Sun StorEdge 6120 Array
ASSY T4 2.5 CONTRLR W/SLED (540-5559-XX) |
StorEdge 6120 and 6320 Arrays with firmware prior to 3.1.x may
experience downtime or data integrity if double disk errors or
back-end loop hangs occur. |
| I1107-1 |
R
|
Sun StorEdge 6320 System
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array |
Batteries may be marked as "failed" and health checks may not
run in Sun StorEdge 6020/6120 Arrays having 3.0.x firmware. |
| I1043-2 |
M
|
Sun StorEdge 6020 Array
Sun StorEdge 6120 Array
Sun StorEdge 6320 System
ASSY, T4 2.5 Controller (540-5559-xx)
|
A specific group of Sun StorEdge 6120 Arrays and 6320 Systems may reset in
rare circumstances due to a controller interrupt caused by an SRAM timing issue.
There may be the potential for silent data corruption if this occurs. |
| I1023-1 |
R
|
StorEdge Network 2GB FC Switch-8 (540-5554)
StorEdge Network 2GB FC Switch-16 (540-5404)
|
StorEdge Network 2GB Switch-8 and Switch-16 units which have been running
for 25 to 28 days may not recognize any attached devices if the
devices are rebooted. This occurs due to a switch firmware bug and can
be resolved with a firmware upgrade. |
| I1009-2 |
M
|
All Sun StorEdge 6020 Arrays
All Sun StorEdge 6120 Arrays |
During power on (cold boot) of a Sun StorEdge 6020/6120 Array
or Sun StorEdge 6320 system one or more drives may come up
in an offline state. |
| I1002-1 |
R
|
All Sun StorEdge 6020 Arrays
All Sun StorEdge 6120 Arrays |
StorEdge 6020/6120 Arrays may automatically power themselves up
after being placed in standby mode. |