Sun StorEdge[tm] 3510 FC Array: Repair Procedures
This section provides tips (when available) for the most common
repair procedures for the StorEdge 3510. The repair procedures are provided
in the following manual:
Also Review the Sun
StorEdge 3510 FRU Replacement Procedures and Sun
StorEdge 3510 RAID Array Installation Checklists.
|
Component
|
Tips
|
|
Disk Drive & Sled
|
-
Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected outages due to a spindle motor issue (FIN I1136-1).
- SCSI Timeout Values may be set too low resulting in intermittent timeouts
due to arbitration, retries, or bad block reallocation (FIN I1058-1).
-
Seagate Cheetah 7 FC-AL and SCSI disk drives with serial numbers
below 60000 are experiencing a higher than expected failure rate due to a spindle
motor issue (FCO A0239-1).
- Issues with Sun StorEdge 3510 FC controller and JBOD
FC cables may result in Amber LED for controllers or drives.
(FCO A0237-2)
|
|
I/O Contoller Modules
|
- Write performance and specifically Sequential write for Sun
StorEdge 3310, 3510, 3511 Storage Array is diminishing when
both controllers are installed
(FIN I1150-1).
- Fix for battery expiration issue of Sun StorEdge 3510 is now available through new SCCLI (1.6.2)
(FIN I1078-1).
- New 3.27R firmware for Sun StorEdge 3510 FC Array provides
enhanced CLI capabilities and functionality with StorADE (FIN I1078-1
).
- A small number of Sun StorEdge 3510 FC Array Controller FRUs may contain
defective firmware (FIN I0953-1).
- Issues with Sun StorEdge 3510 FC controller and JBOD
FC cables may result in Amber LED for controllers or drives.
(FCO A0237-2)
|
|