Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 3510 FC Array: Field Information Notices

 

Implementation (Impl.):
M
= Mandatory (Fully Pro-Active)

C
= Controlled Pro-Active (per Sun Geo Plan)

R
= Reactive (As Required)

FIN
Impl.
Components Affected Description
I1150-1
R
Sun StorEdge 3310 Arrays
Sun StorEdge 3510 Arrays
Sun StorEdge 3511 Arrays
Write performance and specifically Sequential write for Sun StorEdge 3310, 3510, 3511 Storage Array is diminishing when both controllers are installed.
I1149-1
R
Sun StorEdge 3510 FC Arrays
Battery FC 2U (370-5545-05 or lower)
Fix for battery expiration issue of Sun StorEdge 3510 is now available through new SCCLI (1.6.2).
I1136-1
R
Seagate ST336607FC (36GB)
Seagate ST373307FC (73GB)
Seagate ST146807FC (146GB)
Seagate ST336607LC (36GB)
Seagate ST373307LC (73GB)
Seagate ST146807LC (146GB)
Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected outages due to a spindle motor issue.
I1078-1
M
Sun StorEdge 3510 FC Array
RAID Fibre Channel Controller (370-5537-XX)
New firmware release 3.27R for the Sun StorEdge 3510 FC Array addresses several issues for this storage product.
I1067-1
R
Sun StorEdge 3510 Arrays
RAID Fibre Channel Controller (370-5537-xx)
When a Sun StorEdge 3510 FC Array is remotely monitored with StorADE software via the array's ethernet interface, the ethernet port may hang after 1 to 4 hours.
I1058-1
C
Sun StorEdge 3310 Arrays
Sun StorEdge 3510 Arrays
Sun StorEdge 3310/3510 SCSI Timeout Values may be set too low resulting in intermittent timeouts due to arbitration, retries, or bad block reallocation.
R
I/O & Raid Cont FC 1GB 2U (370-5537-02) A small number of Sun StorEdge 3510 FC Array Controller FRUs may contain defective firmware.


 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.
 Legal Terms Privacy Policy Feedback