Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 3310 SCSI Array: Field Information Notices

 

Implementation (Impl.):
M
= Mandatory (Fully Pro-Active)

C
= Controlled Pro-Active (per Sun Geo Plan)

R
= Reactive (As Required)

FIN
Impl.
Components Affected Description
I1150-1
R
Sun StorEdge 3310 Arrays
Sun StorEdge 3510 Arrays
Sun StorEdge 3511 Arrays
Write performance and specifically Sequential write for Sun StorEdge 3310, 3510, 3511 Storage Array is diminishing when both controllers are installed.
I1068-1
R
Sun StorEdge 3310 Arrays
Array Controller (370-5403-01)
Monitoring SE3310 arrays using StorADE can cause performance degradation.
I1058-1
C
Sun StorEdge 3310 Arrays
Sun StorEdge 3510 Arrays
Sun StorEdge 3310/3510 SCSI Timeout Values may be set too low resulting in intermittent timeouts due to arbitration, retries, or bad block reallocation.
I0937-1
R
  • Host/Drv I/O Mod RAID LVD 2U (370-5397-01)
  • Host/Drv I/O Mod JBOD LVD 2U (370-5396-01)
  • Box 2U RAID LVD Chass+Midplane (370-5524-01)
  • Box 2U JBOD LVD Chass+Midplane (370-5393-01)
Instructions for resolving EMI gasket issue during replacement of I/O Module FRU on Sun StorEdge 3310 SCSI Array.
I0929-1
R
Controller (370-5403-01)
Battery LVD (370-5533-01)
Battery FRUs, Controller FRUs and Controllers installed in Sun StorEdge 3310 SCSI Arrays may be missing a battery label showing the manufacture date of the battery.
I0902-1
C
Controller LVD 512 Minnow (370-5403-01) 3310 SCSI Array were shipped to the Field with the "Controller Unique ID" set to a non-zero value. This could cause incorrect device identifiers and an incorrect MAC Address to be presented to the host system when these FRUs are installed into an array. This can result in software applications not being able to access the array due to changed device names. This issue only affects forty-eight (48) RAID Controller Module FRUs shipped between 6-Sep-2002 and 24-Sep-2002 (see FIN for serial numbers affected).