Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

System Boards - Sun Fire V490 Centerplane


Sun Fire V490
Centerplane

A52

501-6911
August 2004
FAB 270-5819-07
SCHIZO 2.5 or ELE 1.1+
>=525-2108-03 OBP 4.15.1

Schizo Data Address Mappings

Schizo Bus  #  Device Device Path Speed
0 EPCI Bus A
(pci8a)
1 PCI Slot 0 pci@8,600000/<device>@1 66MHz
2 PCI Slot 1 pci@8,600000/<device>@2 66MHz
PCI Bus B
(pci8b)
2 PCI Slot 2 pci@8,700000/<device>@2 33MHz
3 PCI Slot 3 pci@8,700000/<device>@3 33MHz
4 PCI Slot 4 pci@8,700000/<device>@4 33MHz
5 PCI Slot 5 pci@8,700000/<device>@5 33MHz
6 IDE pci@8,700000/ide@6 33MHz
1 EPCI Bus C
(pci9a)
1 Cassini 1 pci@9,600000/network@1 66MHz
2 FCAL pci@9,600000/SUNW,qlc@2 66MHz
PCI Bus D
(pci9b)
1,0 EBUS pci@9,700000/ebus@1 33MHz
1,3 USB pci@9,700000/usb@1,3 33MHz
2 Cassini 0 pci@9,700000/network@2 33MHz

Sun Fire V490 Codename: Sebring

Notes

  1. The minimum operating system is Solaris 8 2/04 or Solaris 9 4/04.
  2. The Centerplane provides motherboard functionality, including bridge control of the PCI and Safari busses, and EBus, Ethernet, FC-AL, and I2C controllers.

Component Notes

  1. DC-DC Converter (3.3V) 300-1437 is not available as a FRU.
  2. DC-DC Converter (1.5V) 300-1438 is not available as a FRU.
  3. Ethernet controllers are Cassini+ or Cassini CR .2µm.
  4. ELE 1.1+ became an alternate component for SCHIZO in August 2004. (WO_29730)

References

  1. Sun Fire V490 Server Administration Guide, 817-3951.
  2. Sun Fire V490 Parts Installation and Removal Guide, 817-3952.

 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.