Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

SCSI - PCI Dual Ultra-3 SCSI Host Adapter


PCI Dual Ultra-3 SCSI Host Adapter

Codename: Jasper

Workstations: Ultra 60, 80
Sun Blade 1000, 1500, 2000, 2500
Servers: Enterprise 250, 450, 220R, 420R
Sun Fire 280R, 12K, 15K, E20K, E25K
Sun Fire V480, V490, V880(z), V890
Sun Fire 4800, 4810, 6800, E2900, E4900, E6900
Sun Fire V1280, V120, V210, V240, V250, V440
Telco: Netra 20, 120, 240, 440, 1280
Netra t1400/1405
Disk Arrays: StorEdge 3120, 3310, D2, S1, D240
Tape Libraries: StorEdge L8, L25/L100, L180, L700

Option 6758

375-3057
QLogic QLA10162/66-SUN
3.3/5V 32/64Bit 33/66MHz

Qualified SCSI Cables for Array Connections

StorEdge 3310 and D2
Type Length Mktg Part # Mfg Part #
VHDCI-VHDCI 0.8 m X1136A 530-2982
VHDCI-VHDCI 1.2 m X1137A 530-2983
VHDCI-VHDCI 2 m X1138A 530-2538
VHDCI-VHDCI 4 m X3830B 530-2984
VHDCI-VHDCI 10 m X3831B 530-2985
StorEdge S1
Type Length Mktg Part # Mfg Part #
HD68-VHDCI 0.8 m X1132A 530-2452
HD68-VHDCI 2 m X3832A 530-2453
HD68-VHDCI 4 m X3830A 530-2454
HD68-VHDCI 10 m X3831A 530-2455

Notes

  1. The minimum operating system is Solaris 8 with the Recommended Patch Cluster.
  2. The necessary drivers (SUNWqus & SUNWqusu for 32-bit and 64-bit configurations, and SUNWqusx & SUNWqusux for 64-bit configurations) and patches for this product are not included in Solaris 8 or 9, but must be downloaded.
    Please see the Release Notes, 816-2157, for downloading details.
  3. When using 375-3057 in a multi-initiator configuration with shared StorEdge 3310 or S1 arrays, the jumpers on the board for the appropriate shared SCSI bus must be set to "manual SCSI termination".
    • The jumpers for Port 2 are set to manual termination by factory default:
      (J4 and J5 = 2-3)
    • Prior to May 2003, the factory default of Port 1 was automatic SCSI termination:
      (J8 and J9 = 1-2)
      If Port 1 is shared, these jumpers must be changed to manual termination:
      (J8 and J9 = 2-3)
      This became the default setting of J8 and J9 in May 2003. (see ECO WO_26435)
    For details, see BugID 4836405.
  4. Qualification on Sun Blade 1000 and 2000 is documented in BugID 4644090.

Reference

  1. StorEdge PCI Dual Ultra3 SCSI Host Adapter Installation Guide, 816-2156.
  2. StorEdge PCI Dual Ultra3 SCSI Host Adapter Release Notes, 816-2157.

 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.