Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

I/O - Sun Fire V1280 I/O Board and System Controller


I/O Board and System Controller (IB_SSC)

Sun Fire V1280 / Netra 1280

501-6012 501-6459
I/O Board System Controller
540-4967 540-5290 540-5564 540-5565
IB_SSC Assembly
Sun Fire V1280
FRU Assembly
Sun Fire V1280
IB_SSC Assembly
Netra 1280
FRU Assembly
Netra 1280

PCI Riser Assembly 540-4963 with PCI Riser 501-6013

I/O Board Cable Conections
(under Media Bay cover)

PCI Device Mapping

PHYSICAL
SLOT #
DEVICE PATH I/O
CTLR #
BUS
0 /ssm@0,0/pci@18,700000/<device>@1 0 B
1 /ssm@0,0/pci@18,700000/<device>@2 0 B
2 /ssm@0,0/pci@19,700000/<device>@1 1 B
3 /ssm@0,0/pci@19,700000/<device>@2 1 B
4 /ssm@0,0/pci@19,700000/<device>@3 1 B
5 /ssm@0,0/pci@18,600000/<device>@1 0 A
w /ssm@0,0/pci@18,600000/<device>@2 0 A
x /ssm@0,0/pci@18,700000/<device>@3 0 B
y /ssm@0,0/pci@19,600000/<device>@1 1 A
z /ssm@0,0/pci@19,600000/<device>@2 1 A
w = onboard LSI 1010R SCSI controller
x = onboard CMD646U2 EIDE controller
y = onboard Gigaswift Ethernet controller 0
z = onboard Gigaswift Ethernet controller 1

Sun Fire V1280 Codename: Lightweight 8

Notes

  1. The minimum operating system is Solaris 8 02/02.
  2. The maximum PCI Card length is approximately 197 mm.
  3. The I/O Board and System Controller slot is labeled IB6_SSC1.
  4. The I/O Board and System Controller includes a toothed rack and the chassis includes clutched pinions in the front of slot IB6_SSC1.
  5. Assembly 540-4967 includes Top Cover/Door 540-5216, I/O Board 501-6012, System Controller 501-6459, PCI Riser 501-6013, Dual Serial Cable 530-3101, Ethernet Cable 530-3080, Thermal Fuse Bypass Cable 530-3253, and two 540-5222 Fans.
  6. Assembly 540-5564 includes Top Cover/Door 540-5216, I/O Board 501-6012, System Controller 501-6459, PCI Riser 501-6013, Dual Serial Cable 530-3101, Ethernet Cable 530-3080, Thermal Fuse Cable 530-3198, and two 540-5222 Fans.
  7. Refer to the Install.info file of any Firmware patch for information on firmware verification and compatibility.

References

  1. Sun Fire V1280 Service Manual, 817-0510.
  2. Sun Fire V1280 System Administration Guide, 817-0509.
  3. Sun Fire V1280 Site Preparation and Installation Guide, 817-3333.



I/O Board and System Controller (IB_SSC)

Sun Fire V1280 / Netra 1280 / Sun Fire E2900

501-6012 501-6779
I/O Board System Controller
Version 2
540-4967-07 540-6047 540-6045 540-6048 540-6046
IB_SSC Assembly
V1280
Option X2764A
IB_SSC Assembly
V1280/E2900
FRU Assembly
V1280/E2900
IB_SSC Assembly
Netra 1280
FRU Assembly
Netra 1280

PCI Riser Assembly 540-4963 with PCI Riser 501-6013

I/O Board Cable Conections
(under Media Bay cover)

PCI Device Mapping

PHYSICAL
SLOT #
DEVICE PATH I/O
CTLR #
BUS
0 /ssm@0,0/pci@18,700000/<device>@1 0 B
1 /ssm@0,0/pci@18,700000/<device>@2 0 B
2 /ssm@0,0/pci@19,700000/<device>@1 1 B
3 /ssm@0,0/pci@19,700000/<device>@2 1 B
4 /ssm@0,0/pci@19,700000/<device>@3 1 B
5 /ssm@0,0/pci@18,600000/<device>@1 0 A
w /ssm@0,0/pci@18,600000/<device>@2 0 A
x /ssm@0,0/pci@18,700000/<device>@3 0 B
y /ssm@0,0/pci@19,600000/<device>@1 1 A
z /ssm@0,0/pci@19,600000/<device>@2 1 A
w = onboard LSI 1010R SCSI controller
x = onboard CMD646U2 EIDE controller
y = onboard Gigaswift Ethernet controller 0
z = onboard Gigaswift Ethernet controller 1

Sun Fire V1280 Codename: Lightweight 8
Sun Fire E2900 Codename: Amazon 2

Notes

  1. The minimum E2900 operating system is Solaris 8 02/04 or Solaris 9 04/04.
  2. The maximum PCI Card length is approximately 197 mm.
  3. Version 2 of the IB_SSC includes advanced features, including enhanced error logging. These features require firmware 5.17.0.
  4. The I/O Board and System Controller slot is labeled IB6_SSC1.
  5. The I/O Board and System Controller includes a toothed rack and the chassis includes clutched pinions in the front of slot IB6_SSC1.
  6. Assembly 540-6047 includes Top Cover/Door 540-5216, I/O Board 501-6012, System Controller 501-6459, PCI Riser 501-6013, Dual Serial Cable 530-3101, Ethernet Cable 530-3080, Thermal Fuse Bypass Cable 530-3253, and two 540-5222 Fans.
  7. Assembly 540-6048 includes Top Cover/Door 540-5216, I/O Board 501-6012, System Controller 501-6459, PCI Riser 501-6013, Dual Serial Cable 530-3101, Ethernet Cable 530-3080, Thermal Fuse Cable 530-3198, and two 540-5222 Fans.
  8. Refer to the Install.info file of any Firmware patch for information on firmware verification and compatibility.

References

  1. Sun Fire V1280 Service Manual, 817-0510.
  2. Sun Fire V1280 System Administration Guide, 817-0509.
  3. Sun Fire V1280 Site Preparation and Installation Guide, 817-3333.

 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.
 Legal Terms Privacy Policy Feedback