Sun Microsystems, Inc.   Sun System Handbook - CD 2.1.8 April 2005 Internal/Partner Edition
   Home | Systems | Components | General Info | Search | Feedback

Power Supplies - Delta DPS-1500 - 1500 Watt Power Supply

Delta DPS-1500
1500 Watt Power Supply

Servers: Sun Fire V1280, E2900
Telco: Netra 1280

300-1523 300-1524
Sun Fire V1280/E2900
Type A166
AC Input Power Supply
Netra 1280
Type D142
DC Input Power Supply

Front View

Rear View (300-1523)
    Rear View (300-1524)

AC Input (300-1523)

200-240V Nominal 50-60Hz 9A
Operating Range 180-264Vrms 47-63Hz

DC Input (300-1524)

-40V to -60V per operation on a SELV* rated power source
* SELV = Safety Extra Low Voltage

DC Output

+48V +12VSB
30.2A 4.0A

Sun Fire V1280 Codename: Lightweight 8
Sun Fire E2900 Codename: Amazon 2

Notes

  1. The Power Supply is labeled 200-240V, 50/60Hz, 9A.
  2. The V1280 is labeled 200-240V, 50/60Hz, 18A (9A Max per cord).
  3. Power Supply slots are labeled PS0, PS1, PS2, and PS3.
  4. At least two dedicated branch circuits should be used.
  5. AC Input Source A provides power to PS0 and PS1.
  6. AC Input Source B provides power to PS2 and PS3.

References

  1. Sun Fire V1280 Service Manual, 817-0510.
  2. Sun Fire V1280 System Administration Guide, 817-0509.
  3. Sun Fire V1280 Site Preparation and Installation Guide, 817-3333.
  4. Sun Fire E2900 Site Planning Guide, 817-4052.
  5. Sun Fire E2900 Installation Guide, 817-4053.
  6. Sun Fire E2900 Service Manual, 817-4054.

 Copyright 1994-2005 Sun Microsystems, Inc.,  All rights reserved.