Sun Fire[tm] 6800 Server - Full Components List

Boot PROM
Centerplane
Communication
Ethernet
Fan
Fibre Channel
ID Board
I/O
    Memory
Miscellaneous
Power
Rack
SCSI
System Board
System Controller Board
6800 Exploded View
Cabinet Exploded View
   
Table Legend
[F] = Field Replaceable Unit (FRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system

Boot PROM
Manufacturing
Part #
Patch
n/a 112127
Centerplane
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a 500-4405 501-4405 6 Slot System Centerplane (Factory Installed) 501-5879 [F]
n/a 501-5879 [F] 6 Slot System Centerplane (FRU) n/a
X4070A 595-5384 501-4953 [F] Repeater Board n/a
n/a n/a 501-5005 [F] Power Distribution Centerplane n/a
n/a n/a 501-5006 [F] Fan Distribution Centerplane n/a
Communication
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1071A 605-1636 370-3878 [F] HIPPI/P 1.1 High Performance Interface Board n/a
X1155A 605-1644 370-2728 [F] High Speed Serial Interface (HSI/P) 2.0 n/a
X1157A 605-1623 501-3028 [F] SunATM-155/MFiber PCI 4.0 n/a
X1158A 605-1624 501-3027 [F] SunATM-155/UTP PCI 4.0 n/a
X1159A 605-1625 501-3029 [F] SunATM-622/MFiber PCI 4.0 n/a
X1266A 595-5308 501-5483 [F] Compact PCI (cPCI) SunATM 155 MMF NIC n/a
X1268A 595-5309 501-5564 [F] Compact PCI (cPCI) SunATM 622 MMF NIC n/a
X2156A 605-1644 375-0100 [F] Serial Asynchronous Interface (SAI/P) 3.0 n/a
Ethernet
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1033A 595-4498 501-5019 [F] SunFastEthernet PCI Adapter 2.0 (FE/P) 501-4359 [F]
X1034A 605-1594 501-5406 [F] Quad FastEthernet PCI Card (QFE/P) 501-4366 [F]
X1141A 605-1602 501-4373 [F] Gigabit Ethernet 2.0 PCI Card (GBE/P) n/a
X1234A 595-5307 501-5502 [F] Compact PCI (cPCI) QuadFastEthernet (QFE) n/a
X1261A 595-5310 501-5523 [F] Compact PCI (cPCI) Gigabit Ethernet n/a
Fan
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 540-3631 [F] Fan Tray I/O Area n/a
X4322A 595-5397 540-3632 [F] Fan Tray CPU Area n/a
X4320A 595-5395 540-3662 [F] Fan Tray System Rack n/a
Fibre Channel
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X6727A 595-5853 375-3030 [F] PCI Dual FC Network Adapter+ n/a
X6748A 595-5715 375-0118 [F] Compact PCI (cPCI) Dual Channel FC n/a
X6799A 595-5830 375-3019 [F] PCI Single FC-AL Host Adapter n/a
ID Board
Option # Top Level
Part #
Manufacturing
Part #
Component Type Substitute
Part #
n/a n/a 501-5132 ID Board (SEEPROM), Factory Installed 501-5880 [F]
n/a 501-5880 [F] ID Board (SEEPROM), FRU n/a
I/O
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X4030A 595-5380 501-4868
540-4617 [F]
cPCI I/O Assembly (4 slot) n/a
X4050A 595-5382 501-4404
540-4616 [F]
PCI I/O Assembly (8 slot) n/a
Memory
Option # Top Level
Part #
Manufacturing
Part #
Option Description Substitute
Part #
X7051A 595-5727 501-5030 [F] (512MB)
540-5085
2 GB (4 × 512MB SDRAM DIMMs) n/a
X7053A 595-5729 501-5401 [F] (256MB)
540-5084
1 GB (4 × 256MB SDRAM DIMMs) n/a
X7056A 595-6186 540-5086 [F] (1GB) * 4 GB (4 × 1GB SDRAM DIMMs) 501-6109 [F]
n/a n/a 501-6109 [F] (1GB) * 1GB SDRAM DIMM 540-5086 [F]
1 GB DIMMs 501-6109 and 540-5086 are only supported on Sun Fire 3800-6800 900MHz system boards 540-5051 and 540-5052.
Miscellaneous
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 540-4523 [F] Sun StorEdge D240 Mediatray n/a
Power - DC
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X4302A 595-5392 300-1459 [F] A152, AC-48VDC Power Supply n/a
Power - AC
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X4340A 595-5399 300-1335 [F] AC Redundant Transfer Unit n/a
X4341A 595-5400 300-1396 [F] AC Redundant Transfer Switch n/a
n/a n/a 540-3588 [F] AC Input Box n/a
Rack
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 540-3996 [F] Patch Panel n/a
n/a n/a 540-3883 [F] Frame Manager n/a
n/a n/a n/a Sun Fire Cabinet n/a
SCSI
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1032A 595-4258 501-5656 [F] Single-Ended Ultra/Wide SCSI (SunSwift PCI) + 10/100 Ethernet 501-2741 [F]
X1232A 595-5306 501-5570 [F] Compact PCI (cPCI) Single Ended UltraSCSI + 10/100 Ethernet n/a
X6540A 595-4399 375-0005 [F] Dual Single-Ended Ultra/Wide SCSI (PCI) n/a
X6541A 595-4414 375-0006 [F] Dual Differential Ultra/Wide SCSI (PCI) n/a
X6749A 595-5716 375-0119 [F] Dual Differential Ultra SCSI (cPCI) n/a
System Board
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X4004A 595-5481 540-4729 [F] Sun Fire CPU/Memory Board with 2 UltraSPARC III 750MHZ 0MB n/a
X4005A 595-5478 540-4730 [F] Sun Fire CPU/Memory Board with 4 UltraSPARC III 750MHZ 0MB n/a
X4006A 595-6177 540-5051 [F] Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ 0MB n/a
X4007A 595-6178 540-5052 [F] Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ 0MB n/a
SF-XCPUBD-227 n/a 540-4830 Sun Fire CPU/Memory Board with 2 UltraSPARC III 750MHZ & 2GB Memory 540-4729 [F]
SF-XCPUBD-447 n/a 540-4829 Sun Fire CPU/Memory Board with 4 UltraSPARC III 750MHZ & 4GB Memory 540-4730 [F]
SF-XCPUBD-487 n/a 540-4832 Sun Fire CPU/Memory Board with 4 UltraSPARC III 750MHZ & 8GB Memory 540-4730 [F]
XCPUBD-2029 595-6179 540-4984 Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ, 8MB Ecache each, & 2GB Memory 540-5051 [F]
XCPUBD-2049 595-6200 540-5094 Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ, 8MB Ecache each, & 4GB Memory 540-5051 [F]
XCPUBD-2089 595-6201 540-5095 Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ, 8MB Ecache each, & 8GB Memory 540-5051 [F]
XCPUBD-4049 595-5985 540-4934 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 4GB Memory 540-5052 [F]
XCPUBD-F4089 595-6190 540-4992 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 8GB Memory 540-5052 [F]
XCPUBD-F4169 595-6191 540-4990 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 16GB Memory 540-5052 [F]
XCPUBD-F4329 595-6192 540-4993 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 32GB Memory 540-5052 [F]
System Controller Board
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 501-5407 [F] System Controller Board n/a

Table Legend
[F] = Field Replaceable Unit (FRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system



6800 Exploded View
Cabinet Exploded View

6800 Exploded View
(Click on underlined text to view components)


Table Legend
[F] = Field Replaceable Unit (FRU)

CODE
MANUFACTURING
PART #
DESCRIPTION
1 540-3684 Curved 7-Panel Door
2 240-3530 [F] Air Inlet Cover
3 540-3662 [F] Fan Tray System Rack
4 540-4055 Curved Rear Door
5 240-3531 [F] Air Outlet Cover
NS 180-1943 [F] AC Input Power Cable, Harting Han 6HsB to NEMA L6-30P (North American, Asian)
NS 180-1944 [F] AC Input Power Cable, Harting Han 6HsB to IEC309 (International)
NS 180-1945 [F] Power Cord IEC320 to AMP Mate-N-Lok, 2M
NS 180-1946 [F] AC Power Cable, RTU0 to AC0, .61 Meter
NS 180-1947 [F] Cable AC Power, RTU1 to AC1, 1.5 Meter
NS 180-1948 Power Cord IEC320 to AMP Mate-N-Lok, 3M
NS 240-3580 [F] Redundant Transfer Unit Filler Panel
NS 240-3920 [F] CPU/Memory Board EMI Spring Finger Clip
NS 330-2014 [F] AC Power Key / Door Key
NS 330-2821 [F] System Board Filler Panel (install when servicing)
NS 330-2822 [F] I/O Assembly Filler Panel (install when servicing)
NS 340-4796 Right Side Power Bus Bar
NS 340-4797 Left Side Power Bus Bar
NS 530-2545 [F] System Centerplane to Power Centerplane I2C Cable
NS 530-2546 [F] System Centerplane to Fan Centerplane Power and I2C Cable
NS 530-2560 [F] SSC to Patch Panel Serial Cable
NS 530-2563 [F] Frame Manager to Patch Panel Serial Y Cable
NS 530-2565 [F] Frame Manager to Rack Fan Power Cable
NS 530-2573 [F] Twisted Pair Ethernet, RJ45 Cable
NS 530-2704 [F] Keyswitch Cable
NS 530-2713 Fan Tray to Rack Fan Cable
NS 530-2720 Frame Manager Cable
NS 530-2990 [F] CBL,SHIELD, RJ45, CIP-IWF1, 2M
NS 540-4040 [F] System Board Filler Board
NS 540-4044 [F] System Controller Filler Panel
NS 540-4045 [F] Short PCI Card Filler Board
NS 540-4046 [F] Long PCI Card Filler Board
NS 540-4075 [F] Power Supply Filler Panel
NS 540-4286 I/O Assembly Filler Panel
NS 540-4446 [F] cPCI Card Filler
NS 825-5138 Sun Fire 6800 Document Set




6800 Cabinet Exploded View
(Click on underlined text to view components)


Table Legend
[F] = Field Replaceable Unit (FRU)

CODE MANUFACTURING
PART #
DESCRIPTION
1 540-3684 [F] Curved 7-Panel Door
2
2
540-3353
340-4174
Cabinet Assembly
Cabinet Frame
3 340-4374 Side Panel
4 330-6728 Cosmetic Cap
NS 540-4055 [F] Curved Rear Door
NS 180-1943 [F] AC Input Power Cable, Harting Han 6HsB to NEMA L6-30P (North American, Asian)
NS 180-1944 [F] AC Input Power Cable, Harting Han 6HsB to IEC309 (International)
NS 180-1945 [F] Power Cord IEC320 to AMP Mate-N-Lok, 2M
NS 180-1946 [F] AC Power Cable, RTU0 to AC0, .61 Meter
NS 180-1947 [F] Cable AC Power, RTU1 to AC1, 1.5 Meter
NS 180-1948 Power Cord IEC320 to AMP Mate-N-Lok, 3M
NS 230-1536 Cabinet Leveler Foot (×4)
NS 240-3379 Swivel Caster
NS 240-3808 Anti-Tilt Bar Leveler Foot (×2)
NS 530-2560 [F] System Controller to Patch Panel Serial Cable Caster
NS 530-2563 [F] Frame Manager to Patch Panel Serial Y Cable
NS 530-2565 [F] Fan Power Cable, Frame Manager to Fan Tray
NS 530-2704 [F] Key Switch Cable, Frame Manager to RTU

 