Sun Fire[tm] 4800/4810 Server - Full Components List

Boot PROM
Centerplane
Communication
Ethernet
Fan
Fibre Channel
ID Board
I/O
    Memory
Miscellaneous
Power
Rack
SCSI
System Board
System Controller Board
4800 Exploded View
4810 Exploded View
   
Table Legend
[F] = Field Replaceable Unit (FRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system

Boot PROM
Manufacturing
Part #
Patch
n/a 112127
Centerplane
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a 599-2185 501-4406 3 Slot System Centerplane (4800), Factory Installed 501-5877 [F]
n/a 501-5877 [F] 3 Slot System Centerplane (4800), FRU n/a
n/a 599-2210 501-4970 3 Slot System Centerplane (4810), Factory Installed 501-5878 [F]
n/a 501-5878 [F] 3 Slot System Centerplane (4810), FRU n/a
n/a n/a 501-5029 [F] Power Distribution Centerplane (4810) n/a
X4070A 595-5384 501-4953 [F] Repeater Board n/a
Communication
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1071A 605-1636 370-3878 [F] HIPPI/P 1.1 High Performance Interface Board n/a
X1155A 605-1644 370-2728 [F] High Speed Serial Interface (HSI/P) 2.0 n/a
X1157A 605-1623 501-3028 [F] SunATM-155/MFiber PCI 4.0 n/a
X1158A 605-1624 501-3027 [F] SunATM-155/UTP PCI 4.0 n/a
X1159A 605-1625 501-3029 [F] SunATM-622/MFiber PCI 4.0 n/a
X1266A 595-5308 501-5483 [F] Compact PCI (cPCI) SunATM 155 MMF NIC n/a
X1268A 595-5309 501-5564 [F] Compact PCI (cPCI) SunATM 622 MMF NIC n/a
X2156A 605-1644 375-0100 [F] Serial Asynchronous Interface (SAI/P) 3.0 n/a
Ethernet
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1033A 595-4498 501-5019 [F] SunFastEthernet PCI Adapter 2.0 (FE/P) 501-4359 [F]
X1034A 605-1594 501-5406 [F] Quad FastEthernet PCI Card (QFE/P) 501-4366 [F]
X1141A 605-1602 501-4373 [F] Gigabit Ethernet 2.0 PCI Card (GBE/P) n/a
X1234A 595-5307 501-5502 [F] Compact PCI (cPCI) QuadFastEthernet (QFE) n/a
X1261A 595-5310 501-5523 [F] Compact PCI (cPCI) Gigabit Ethernet n/a
Fan
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 540-3586 [F] Fan Tray CPU Area (4800) n/a
X4321A 595-5732 540-3639 [F] Fan Tray (4810) n/a
n/a n/a 540-4344 [F] Fan Tray Top I/O Area (4800) n/a
X4324A 595-5731 540-4345 [F] Fan Tray Bottom I/O Area (4800) n/a
Fibre Channel
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X6727A 595-5853 375-3030 [F] PCI Dual FC Network Adapter+ n/a
X6748A 595-5715 375-0118 [F] Compact PCI (cPCI) Dual Channel FC n/a
X6799A 595-5830 375-3019 [F] PCI Single FC-AL Host Adapter n/a
ID Board
Option # Top Level
Part #
Manufacturing
Part #
Component Type Substitute
Part #
n/a n/a 501-5132 ID Board (SEEPROM), Factory Installed 501-5880 [F]
n/a 501-5880 [F] ID Board (SEEPROM), FRU n/a
I/O
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X4030A 595-5380 501-4868
540-4617 [F]
cPCI I/O Assembly (4 slot) n/a
X4050A 595-5382 501-4404
540-4616 [F]
PCI I/O Assembly (8 slot) n/a
Memory
Option # Top Level
Part #
Manufacturing
Part #
Option Description Substitute
Part #
X7051A 595-5727 501-5030 [F] (512MB)
540-5085
2 GB (4 × 512MB SDRAM DIMMs) n/a
X7053A 595-5729 501-5401 [F] (256MB)
540-5084
1 GB (4 × 256MB SDRAM DIMMs) n/a
X7056A 595-6186 540-5086 [F] (1GB) * 4 GB (4 × 1GB SDRAM DIMMs) 501-6109 [F]
n/a n/a 501-6109 [F] (1GB) * 1GB SDRAM DIMM 540-5086 [F]
1 GB DIMMs 501-6109 and 540-5086 are only supported on Sun Fire 3800-6800 900MHz system boards 540-5051 and 540-5052.
Miscellaneous
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 540-4523 [F] Sun StorEdge D240 Mediatray n/a
Power - DC
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X4301A 595-5391 300-1460 [F] A153, AC-48VDC Power Supply (4800) n/a
X4302A 595-5392 300-1459 [F] A152, AC-48VDC Power Supply (4810) n/a
Power - AC
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 540-4346 [F] AC Input Box n/a
Rack
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
SF-CAB n/a SF-CAB Sun Fire Cabinet n/a
SCSI
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1032A 595-4258 501-5656 [F] Single-Ended Ultra/Wide SCSI (SunSwift PCI) + 10/100 Ethernet 501-2741 [F]
X1232A 595-5306 501-5570 [F] Compact PCI (cPCI) Single Ended UltraSCSI + 10/100 Ethernet n/a
X6540A 595-4399 375-0005 [F] Dual Single-Ended Ultra/Wide SCSI (PCI) n/a
X6541A 595-4414 375-0006 [F] Dual Differential Ultra/Wide SCSI (PCI) n/a
X6749A 595-5716 375-0119 [F] Dual Differential Ultra SCSI (cPCI) n/a
System Board
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X4004A 595-5481 540-4729 [F] Sun Fire CPU/Memory Board with 2 UltraSPARC III 750MHZ 0MB n/a
X4005A 595-5478 540-4730 [F] Sun Fire CPU/Memory Board with 4 UltraSPARC III 750MHZ 0MB n/a
X4006A 595-6177 540-5051 [F] Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ 0MB n/a
X4007A 595-6178 540-5052 [F] Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ 0MB n/a
SF-XCPUBD-227 n/a 540-4830 Sun Fire CPU/Memory Board with 2 UltraSPARC III 750MHZ & 2GB Memory 540-4729 [F]
SF-XCPUBD-447 n/a 540-4829 Sun Fire CPU/Memory Board with 4 UltraSPARC III 750MHZ & 4GB Memory 540-4730 [F]
SF-XCPUBD-487 n/a 540-4832 Sun Fire CPU/Memory Board with 4 UltraSPARC III 750MHZ & 8GB Memory 540-4730 [F]
XCPUBD-2029 595-6179 540-4984 Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ, 8MB Ecache each, & 2GB Memory 540-5051 [F]
XCPUBD-2049 595-6200 540-5094 Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ, 8MB Ecache each, & 4GB Memory 540-5051 [F]
XCPUBD-2089 595-6201 540-5095 Sun Fire CPU/Memory Board with 2 UltraSPARC III 900MHZ, 8MB Ecache each, & 8GB Memory 540-5051 [F]
XCPUBD-4049 595-5985 540-4934 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 4GB Memory 540-5052 [F]
XCPUBD-F4089 595-6190 540-4992 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 8GB Memory 540-5052 [F]
XCPUBD-F4169 595-6191 540-4990 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 16GB Memory 540-5052 [F]
XCPUBD-F4329 595-6192 540-4993 Sun Fire CPU/Memory Board with 4 UltraSPARC III 900MHZ, 8MB Ecache each, & 32GB Memory 540-5052 [F]
System Controller Board
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 501-5407 [F] System Controller Board n/a

Table Legend
[F] = Field Replaceable Unit (FRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system


4800 Exploded View
4810 Exploded View

4800 Exploded View
CODE
MANUFACTURING
PART #
DESCRIPTION
1 330-2539 Top Cover
2 330-2546 Right Rear Side Cover
3 330-2545 Left/Right Side Cover
4 330-2547 Left Rear Side Cover
5 240-3534 [F] Air Inlet Cover
6 240-4636 Air Outlet Cover
7 540-4636 [F] Upper Left Rear Cover
NS 180-1945 [F] Power Cord 16/20A IEC 2.5 Meter (4800)
NS 240-3243 Caster
NS 240-3920 [F] CPU/Memory Board EMI Spring Finger Clip
NS 330-2014 [F] AC Power Key / Door Key
NS 330-2821 [F] System Board Filler Panel (install when servicing)
NS 330-2822 [F] I/O Assembly Filler Panel (install when servicing)
NS 340-4931 [F] Power Supply Filler Panel (4800)
NS 530-1343 [F] Power Cord 240V power to IEC
NS 530-1351 [F] Power Cord 230V 6 to 15 pin IEC
NS 530-1869 [F] Serial Breakout Cable 25M to 25F, 25F
NS 530-2886 [F] System Centerplane Power Cable (AC Input to Centerplane)
NS 530-2887 [F] Centerplane to Front Fan Tray Cable
NS 540-3647 Lower Front Door
NS 540-3898 Upper Front Bezel
NS 540-4040 [F] System Board Filler Board
NS 540-4045 [F] Short PCI Card Filler Board
NS 540-4046 [F] Long PCI Card Filler Board
NS 540-4286 I/O Assembly Filler Panel
NS 540-4402 [F] Bottom I/O Fan Tray Filler Panel
NS 540-4636 [F] Air Outlet Cover (4800)
NS 595-5403 Deskside Conversion Assembly, Option 4344

Table Legend
[F] = Field Replaceable Unit (FRU)

4810 Exploded View
CODE
MANUFACTURING
PART #
DESCRIPTION
1 240-3534 [F] Air Inlet Cover
2 240-3535 [F] Air Outlet Cover (4810)
NS 180-1945 [F] Mate-N-Lokto IEC320 Power Cord, option X319A
NS 240-3920 [F] CPU/Memory Board EMI Spring Finger Clip
NS 330-2014 [F] AC Power Key / Door Key
NS 330-2821 [F] System Board Filler Panel (install when servicing)
NS 330-2822 [F] I/O Assembly Filler Panel (install when servicing)
NS 530-1351 [F] Power Cord 230V 6 to 15 pin IEC, option X320A
NS 530-1869 [F] Serial Breakout Cable 25M to 25F, 25F
NS 530-2543 [F] System Centerplane Power Cable (4810)
NS 540-4040 [F] CPU/Memory Board Filler Board
NS 540-4045 [F] Short PCI Card Filler Board
NS 540-4046 [F] Long PCI Card Filler Board
NS 540-4075 [F] Power Supply Filler Panel (4810)
NS 540-4200 [F] Fan Filler Panel (4810)
NS 540-4286 I/O Assembly Filler Panel