Sun Fire[tm] 15K Server - Full Components List
| Centerplane |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| n/a |
n/a |
501-4936 [F]
540-5150 |
Sun Fireplane Interconnect
Power Cabinet
Assembly (replaced 540-4812) |
n/a
n/a |
| X4500A |
595-5188 |
501-6028
501-5179 [F]
370-4012
|
System Expander Assembly
 System
Expander Board
370-4012
CDC SRAM DIMM |
n/a
n/a
n/a |
| n/a |
n/a |
501-5183 [F] |
Power Centerplane |
n/a |
| n/a |
n/a |
501-5271 [F] |
Fan Backplane |
n/a |
| n/a |
n/a |
501-6029
501-5378
[F] |
Centerplane Support Board Assembly
Centerplane
Support Board FRU |
n/a |
| n/a |
n/a |
540-3993 [F] |
System Controller/Centerplane Support Board Carrier
Plate |
n/a |
| n/a |
n/a |
540-4085 [F] |
System Expander Carrier Plate (Slots 1, 2, 3,
6, 7, 8, 10, 11, 12, 15, 16, and 17) |
n/a |
| n/a |
n/a |
540-4427 |
Carrier Plate (Slots 0, 9) |
n/a |
| n/a |
n/a |
540-4428 |
Carrier Plate (Slots 4, 5, 13, 14) |
n/a |
| Communication |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| X1157A |
605-1623 |
501-3028
[F] |
SunATM-155/MFiber 4.0 |
n/a |
| X1158A |
605-1624 |
501-3027
[F] |
SunATM-155/UTP 4.0 |
n/a |
| X1159A |
605-1625 |
501-3029
[F] |
SunATM-622/MFiber 4.0 |
n/a |
| Disks |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| n/a |
n/a |
390-0038
[F] |
Seagate ST318404LC (18.2GB - 10000
RPM) |
n/a |
| n/a |
n/a |
390-0043 |
Fujitsu MAJ3182M (18.2GB - 10000
RPM) |
n/a |
| Sun StorEdge[tm] S1
* |
| * - Primary boot device for Sun Fire 15K. |
| Ethernet
|
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| X1034A |
605-1594 |
501-5406
[F] |
Sun Quad FastEthernet (QFE/P) |
n/a |
| X1141A |
605-1601 |
501-4373
[F] |
Gigabit Ethernet 2.0 (GBE/P) |
n/a |
| X1150A |
595-5812 |
501-5902
[F] |
Sun GigaSwift Ethernet UTP |
n/a |
| Fan Tray |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| n/a |
n/a |
540-4050 [F] |
Fan Tray |
n/a |
| Fibre Channel |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| X6727A |
595-5853 |
375-3030
[F] |
PCI Dual FC Network Adapter+ |
n/a |
| X6799A |
595-5830 |
375-3019
[F] |
PCI Single FC Host Adapter |
n/a |
| I/O |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
Previous
Part # |
X4575A
n/a |
595-5187
n/a |
501-6302
501-5397
[F] |
Hot Swap PCI (hsPCI) Board with PCI Cassettes
hsPCI
Board without PCI Cassettes |
n/a
n/a |
501-6030
n/a |
| n/a |
n/a |
501-5599
[F] |
3.3V Hot Swap PCI (hsPCI) Cassette |
n/a |
n/a |
| n/a |
n/a |
501-5600
[F] |
5.0 V Hot Swap PCI (hsPCI) Cassette |
n/a |
n/a |
| Memory
|
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Option Description |
Substitute
Part # |
| X7051A |
595-5727 |
501-5030
[F] (512MB) |
2 GB (4 × 512MB SDRAM DIMMs) |
n/a |
| X7053A |
595-5729 |
501-5401
[F] (256MB) |
1 GB (4 × 256MB SDRAM DIMMs) |
n/a |
| X7056A |
595-6186 |
540-5086
[F] (1GB) |
4 GB (4 × 1GB SDRAM DIMMs) |
501-6109
[F] |
| n/a |
n/a |
501-6109
[F] (1GB) |
1GB SDRAM DIMM |
540-5086
[F] |
| n/a |
595-5011 |
501-5209
[F] |
128MB Memory Board (for CP1500 on system controller) |
n/a |
| n/a |
595-5097 |
501-5388
[F] |
256MB Memory Board (for CP1500 on system controller) |
540-4349 [F] |
| Miscellaneous
|
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Option Description |
Substitute
Part # |
| n/a |
n/a |
370-4347 [F] |
Plenum Air Filter (used in assembly 540-3985) |
n/a |
| n/a |
n/a |
370-4364 [F] |
Air Filter |
n/a |
| n/a |
n/a |
340-5614 |
Top Honeycomb Filter |
n/a |
| n/a |
n/a |
340-5615 |
Front Honeycomb Filter |
n/a |
| Power |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| n/a |
n/a |
300-1413
[F] |
Power Supply |
n/a |
| n/a |
n/a |
370-4055 [F] |
Power Supply Chassis |
n/a |
| Rack |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| n/a |
n/a |
340-7192 [F] |
Left Side Panel with logo |
n/a |
| n/a |
n/a |
340-7193 [F] |
Right Side Panel with logo |
n/a |
| n/a |
n/a |
540-4080
[F] |
Front Access Door (right) |
n/a |
| n/a |
n/a |
540-4081 [F] |
Rear Access Door (right) |
n/a |
| n/a |
n/a |
540-4357 [F] |
Kick Plate Assembly |
n/a |
| n/a |
n/a |
540-4560 [F] |
Rear Plenum Panel |
n/a |
| n/a |
n/a |
540-4561 [F] |
Front Plenum Panel |
n/a |
| n/a |
n/a |
540-5046 [F] |
Left Front Door with logo |
n/a |
| n/a |
n/a |
540-5077 [F] |
Left Rear Door with EMI |
n/a |
| n/a |
n/a |
540-5151 |
Processor Cabinet |
n/a |
| X9660A |
595-5204 |
n/a |
72" StorEdge Cabinet 1RU Air Baffle |
n/a |
| 9819AR5 |
596-2765 |
n/a |
72 inch StorEdge Cabinet Fan Assembly (Optional) |
n/a |
| X9818A |
595-4999 |
370-3675 |
72 inch StorEdge Expansion Cabinet Front Door
Kit (Optional) |
n/a |
| SG-ARY030A |
595-4706 |
540-3707
|
72 inch StorEdge Expansion Cabinet (Peripheral
Cabinet) |
n/a |
| Removable Media |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| n/a |
n/a |
390-0025
[F] |
10X DVD-ROM Drive |
n/a |
| n/a |
n/a |
390-0027
[F] |
20-40GB 4 mm DDS-4 Tape Drive |
n/a |
| SCSI |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| X1032A |
595-4258 |
501-5656
[F] |
Single-Ended Ultra/Wide SCSI (SunSwift PCI) |
n/a |
| X2222A |
595-5624 |
501-5727 [F]
|
Dual FastEthernet + Dual SCSI PCI Adapter |
n/a |
| X6541A |
595-4414 |
375-0006
[F] |
Dual Differential Ultra/Wide SCSI (PCI) |
n/a |
| System Board |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| X4007A |
595-6178 |
540-5052
[F] |
Sun Fire CPU/Memory Board with 4 UltraSPARC III
900MHZ 0MB |
n/a |
| X4525A |
595-4887 |
501-6138 [F] |
MaxCPU Board 900MHz |
n/a |
| XCPUBD-4049 |
595-5985 |
540-4934 |
Sun Fire CPU/Memory Board with 4 UltraSPARC III
900MHZ, 8MB Ecache each, & 4GB Memory |
540-5052
[F] |
| XCPUBD-F4089 |
595-6190 |
540-4992 |
Sun Fire CPU/Memory Board with 4 UltraSPARC III
900MHZ, 8MB Ecache each, & 8GB Memory |
540-5052
[F] |
| XCPUBD-F4169 |
595-6191 |
540-4990 |
Sun Fire CPU/Memory Board with 4 UltraSPARC III
900MHZ, 8MB Ecache each, & 16GB Memory |
540-5052
[F] |
| XCPUBD-F4329 |
595-6192 |
540-4993 |
Sun Fire CPU/Memory Board with 4 UltraSPARC III
900MHZ, 8MB Ecache each, & 32GB Memory |
540-5052
[F] |
| System
Controller |
| Option # |
Top Level
Part # |
Manufacturing
Part # |
Description |
Substitute
Part # |
| n/a |
501-5994 |
501-5121
[F] |
System Control Board |
n/a |
| n/a |
540-4813 |
501-5418 [F] |
System Control Peripheral Board |
n/a |
| n/a |
595-5253 |
501-5473 [F] |
0MB 440MHz CP1500 CPU, requires memory |
n/a |
| Table Legend |
[F] = Field Replaceable Unit
(FRU)
[S] = Supported, but can no longer be ordered
with this system
[N] = No longer supported for this system
|
Exploded View
| Table Legend |
| [F] = Field Replaceable Unit (FRU) |
| CODE |
MANUFACTURING
PART #
|
DESCRIPTION
|
|
1
|
595-2508 |
Sun Fire 15K Assembly (replaced 599-2264) |
|
2
|
540-3883 [F] |
Top Cap / Frame Manager |
|
3
|
540-4390 [F] |
Top Cap / Frame Manager Extension |
|
4
|
340-7193 [F] |
Sun Side Panel (replaced 340-5107) |
|
5
|
340-7192 [F] |
Logo Side Panel (replaced 340-6442) |
|
6
|
370-4055 [F] |
Power Supply Chassis |
|
7
|
501-6029
501-5378
[F] |
Centerplane Support Board Assembly
Centerplane
Support Board FRU |
|
8
|
501-5183 [F] |
Power Centerplane |
|
9
|
501-5271 [F] |
Fan Backplane |
| NS |
180-1943 [F] |
AC Power Cable, Domestic (Option X3800A), L6-30P (cord up) |
| NS |
180-1944 |
AC Power Cable, International (Option X3848A), IEC 309 (cord
up) |
| NS |
180-1954 [F] |
Power Cord for 72 inch StorEdge Expansion Cabinet, US (Option
X3858A), L6-30P (cord down) |
| NS |
180-1955 |
Power Cord for 72 inch StorEdge Expansion Cabinet, International
(Option X3859A), IEC 309 (cord down) |
| NS |
250-1639 [F] |
18 in. lb Preset Torque Screwdriver |
| NS |
250-1640 [F] |
Magnetic Screwdriver with 7 1/4" Shaft for Fan Backplane |
| NS |
340-4726 |
Chassis |
| NS |
340-5873 |
Left Trim Panel |
| NS |
340-5874 |
Right Trim Panel |
| NS |
340-5901 |
DC Cover |
| NS |
340-6021 |
Top, Rear Trim Panel |
| NS |
340-6452 |
Lower Trim Panel |
| NS |
340-6454 |
Top, Front Trim Panel |
| NS |
530-2799 |
Ethernet Cable |
| NS |
530-2817 |
LED Cable |
| NS |
530-2920 [F] |
System Control Peripheral Board Power Cable |
| NS |
530-2956 [F] |
System Controller CPU Cable |
| NS |
530-3045 [F] |
System Control Peripheral Board SCSI Cable |
| NS |
540-4166 [F] |
I/O FillerPanel (used as required), Option X4615A |
| NS |
540-4201 [F] |
CPU Filler Panel (use as required), Option X4610A |
| NS |
565-1638
530-2766 [F]
530-2771 [F]
530-2772 [F]
530-2773 [F]
530-2781
530-2767
[F]
530-2768
[F]
530-2769
[F]
530-2770
[F]
530-2757
[F]
530-2758
[F]
530-2793
[F]
530-2794
[F]
530-2795
[F]
530-2796
[F]
530-2854
[F]
530-2855
[F]
530-2856
[F]
530-2857
[F]
530-2858
[F]
530-2859
[F] |
Cable Kit
Fan Power Cable
48Vdc Power Cable
48Vdc Crossover
Cable
I2C Cable
Cable Kit
Upper Front
Fan I2C Cable
Lower Front
Fan I2C Cable
Upper Rear
Fan I2C Cable
Lower Rear
Fan I2C Cable
Front Expander
Power Cable
Rear Expander
Power Cable
Front Control
0 Cable
Front Control
1 Cable
Rear Control
0 Cable
Rear Control
1 Cable
Front Power
Control Cable
Rear Power
Control Cable
Internal
Top Cap / Frame Manager Power Cable
External
Top Cap / Frame Manager Power Cable
Internal
RS232 Cable
External
RS232 Cable |
Sun Proprietary/Confidential
|