cPCI I/O Board

Sun Fire 3800

Option 4040

501-5531 540-4591
cPCI Assembly FRU Assembly

6-Slot cPCI Riser 501-5532

Notes

  1. The minimum operating system is Solaris 8 4/01.
  2. The 6-Slot cPCI I/O Board is not hot pluggable.
  3. I/O Board slots are labeled IB6 and IB8.
  4. The I/O Board includes an I/O Board, cPCI Riser, and Cardcage.
  5. Chassis labels include the abbreviated name and number.
  6. The right to left system installation sequence is IB8 then IB6.
  7. Install Filler Board 540-4446 in all empty cPCI board slots.
  8. Install Filler Panel 330-3155 when servicing a cPCI I/O board slot.

References

  1. cPCI I/O Installation Guide, 806-2951.
  2. Powering On and Off Guide, 806-2956.